Nutriport low profile device - Size: 20F Length: 3 cm
Product information
- Quantity Unit Single
- Product Code 9592260
Sorry. This item is out of stock
Description
The Nutriport Low Profile Device is a specialized mini button gastrostomy tube designed to provide enteral feeding for patients who require nutritional support beyond oral intake. This device is inserted directly into the stomach through a stoma on the abdominal wall, allowing for the delivery of liquid food, formula, or medication.
Key Features
- Low-Profile Design: Sits at skin level to enhance comfort and minimize the risk of accidental dislodgement.
- Apple-Shaped Balloon: Expands horizontally for secure placement at the gastrostomy site.
- Tapered Transition: Ensures a snug fit with a durable anti-reflux valve.
- External Design: "Raised feet" feature reduces skin irritation.
- Feeding Port: Incompatible with luer-lock or IV connectors to prevent misconnections. The purple color clearly indicates it is for nutritional use only.
Material and Safety
- Medical-Grade Silicone: Constructed from 100% medical-grade silicone, DEHP-free and latex-free.
- Sterilization: Sterilized using ethylene oxide.
- Classification: Recognized as a Class II medical device in gastroenterology.
Sizes and Dimensions
- Available Sizes: Ranges from 12 Fr to 24 Fr.
- Tube Lengths: From 1.0 cm to 5.0 cm.
Additional Features
- Adjustable Balloon: Allows for a customized fit, recommended to be filled with sterile water.
- Ease of Placement: Designed for easy insertion and enhanced patient comfort.
Use Cases
Ideal for both pediatric and adult patients in need of enteral feeding, particularly beneficial for those at higher risk of accidental tube dislodgement. Suitable for use in both clinical and home settings, especially once caregivers are comfortable with the replacement process.
Maintenance and Replacement
- Balloon Longevity: Typically lasts between 3 to 6 months, depending on care and usage.
- Replacement Timing: Should occur only after the gastrostomy tract has matured, generally 1 to 4 weeks post-initial placement.
- Care Instructions: Ensure the replacement button is intact, correctly sized, and that the port flushes properly.
Included Components
For kits, the following components are included:
- Skin-level gastrostomy device
- Step-up shim
- Bolus feeding set
- Continuous feeding set with ClipStar Enteral Security Clip
- 60 cc irrigation syringe
- 12 cc syringe
- Gauze pads
This comprehensive design ensures that the Nutriport Low Profile Device meets the diverse needs of patients requiring reliable and comfortable enteral feeding solutions.