MIC-KEY Low-Profile GJ Feeding Tube (18Fr · 2.5cm · 45cm)

Product information

  • Quantity Unit Carton
  • Contains 1 Singles
  • Product Code None

$764.40 incl GST

Description

Overview

  • Low-profile, skin-level, double-lumen enteral device placed through a gastric stoma with the distal limb positioned in the jejunum.
  • Supports simultaneous jejunal feeding and gastric decompression/venting.
  • Suitable for pediatric and adult patients.

Ports and functions

  • JEJUNAL port: delivers nutrition into the small intestine (post-pyloric).
  • GASTRIC port: decompression/venting as clinically directed (e.g., gravity drainage or low intermittent suction).
  • BAL (balloon) port: for inflation/deflation of the internal retention balloon only.
  • One-way valves in JEJUNAL and GASTRIC ports open when a MIC-KEY extension set is attached.
  • No dedicated medication port; medications may be administered via the jejunal or gastric lumen per clinical direction.

Design and retention

  • Internal inflatable balloon for retention with a low-profile external bolster.
  • Weighted jejunal section helps maintain jejunal placement.
  • Multiple jejunal exit ports for flow distribution.
  • Radiopaque stripe for imaging confirmation.
  • Tapered distal tip to aid placement.

Connectivity and compatibility

  • Uses MIC-KEY extension sets; brand-specific and not interchangeable with other low-profile button brands.
  • ENFit standard at the feeding-line side of the extension; avoid overtightening ENFit connections.
  • Attachment technique: align the black marks on the button and extension, push in firmly while holding both, then turn clockwise up to three-quarters of a turn to lock; twist to unlock. To disconnect, hold the center of the button and pull straight out from the hard plastic connector.
  • Offered in ENFit configurations; confirm the required connector configuration for the intended system.

Sizes and options

  • French sizes: 14, 16, 18, 22 Fr.
  • Jejunal lengths: 15, 22, 30, 45 cm (measured from the distal aspect of the retention balloon to the tip).
  • Stoma lengths: approximately 1.0–7.0 cm (availability varies by French size).

Handling and maintenance

  • Do not rotate GJ tubes (rotation applies to gastrostomy tubes, not GJ tubes).
  • Do not use the balloon inflation valve for food or medication; use only the designated feeding/drainage ports.
  • Balloon volumes are not checked routinely; if increased leakage or looseness is noted, check per device guidance using a 10 mL luer slip syringe.
  • For flushing, use warm water with a gentle pulsatile push–pull motion; do not use excessive force and do not use carbonated beverages.

Troubleshooting

  • Leakage may result from an internal valve issue, constipation/slow gastric emptying, a plugged port, or worn extension tip/locking notch. Management may include treating constipation, slowing feeds, and flushing as above. If unresolved, keep the cap closed or leave an extension plugged into the port until assessed.
  • If the jejunal limb migrates back into the stomach, or the tube splits above the jejunum, cease feeds if gastric feeding is unsafe and arrange assessment/replacement.

Materials, sterility, and usage

  • Medical-grade silicone; not made with natural rubber latex.
  • Sterile (gamma sterilized).
  • Single-use only; do not re-use, re-process, or re-sterilize.
  • Prescription device (Rx only).

Kit contents

  • GJ feeding tube plus MIC-KEY ENFit extension sets for continuous and/or bolus feeding (contents may vary by configuration).