MIC-KEY Low-Profile GJ Feeding Tube (18Fr · 2.3cm · 30cm)

Product information

  • Quantity Unit Carton
  • Contains 1 Singles
  • Product Code 6761687305

$764.40 incl GST

Description

The MIC-KEY (Avanos Medical, Inc.) Low-Profile Gastric-Jejunal (GJ) Feeding Tube Kit is a skin-level device designed to provide simultaneous jejunal feeding and gastric decompression/venting through an existing gastric stoma. This configuration features a 16 Fr outer diameter, 2.0 cm stoma length, and 30 cm jejunal length. The low-profile external bolster (“button”) connects to compatible extension sets while an internal inflatable balloon helps retain the device. The non-ENFit, catheter-tip connectivity supports established care protocols where ENFit is not in use.

Design and Ports

  • Low-profile external bolster with inflatable internal retention balloon
  • JEJUNAL port: one-way valve for delivering nutrition to the small intestine (activated by MIC-KEY Extension Sets)
  • GASTRIC port: one-way valve for decompression/venting (activated by MIC-KEY Extension Sets)
  • BAL port: for balloon inflation/deflation
  • Weighted jejunal limb to help maintain jejunal placement
  • Multiple jejunal exit ports for distribution
  • Radiopaque stripe for imaging visibility
  • Tapered distal tip to aid placement

Compatibility and Connectivity

  • Non-ENFit configuration; feed set connector type: catheter tip
  • Compatible with MIC-KEY Extension Sets for jejunal and gastric ports

Materials and Regulatory

  • Medical-grade silicone; latex-free
  • Sterile (gamma sterilized)
  • Single-use; prescription device (Rx only)

Specifications (This Configuration)

  • Outer diameter: 16 Fr
  • Stoma length: 2.0 cm
  • Jejunal length: 30 cm
  • Balloon inflation: 3 mL sterile or distilled water (maximum 5 mL)

Kit Contents (Typical MIC-KEY GJ Kit)

  • Continuous feed extension set, 12 in
  • Bolus feed extension set, 12 in
  • 35 mL syringe (for venting/priming/flushing)
  • 6 mL Luer Slip syringe (for balloon inflation/deflation)

Use Considerations

  • For appropriately selected patients requiring jejunal feeding with gastric decompression via a gastric stoma
  • Verify placement and functionality per institutional protocol; radiopaque stripe aids imaging confirmation
  • Check balloon volume in accordance with clinical guidelines; use only sterile or distilled water for inflation