MIC-KEY Low-Profile GJ Feeding Tube (14Fr · 4.5cm · 45cm)

Product information

  • Quantity Unit Carton
  • Contains 1 Singles
  • Product Code 6761688115

$764.40 incl GST

Description

Overview

The Avanos MIC-KEY Low-Profile Gastric-Jejunal (GJ) Feeding Tube Kit is a skin-level, double-lumen enteral device placed via a gastric stoma to enable simultaneous jejunal feeding and gastric decompression/venting for pediatric and adult patients.

Design and ports

  • Internal inflatable balloon retention with a low-profile external bolster.
  • Three labeled access points on the bolster:
  • JEJUNAL: post-pyloric feeding to the jejunum.
  • GASTRIC: drainage/decompression via low intermittent suction or gravity.
  • BAL: balloon inflation/deflation.
  • One-way valves in the JEJUNAL and GASTRIC ports open when a MIC-KEY Extension Set is attached.

Connectivity and extension sets

  • Available in ENFit and non-ENFit configurations; ports are accessed using MIC-KEY Extension Sets.
  • ENFit kits include MIC-KEY ENFit extension sets; non-ENFit uses a catheter-tip feed-set connector.

Key features

  • Weighted jejunal segment helps maintain placement.
  • Multiple jejunal exit ports for distribution.
  • Radiopaque stripe enhances imaging visibility.
  • Tapered distal tip to facilitate advancement.
  • No dedicated medication port; administer medications via gastric or jejunal port per clinical direction.

Materials and sterility

  • Medical-grade silicone; not made with natural rubber latex.
  • Sterile, gamma sterilized; single-use; prescription device (Rx only).
  • CE marked (Class IIb); manufactured in Mexico at an ISO 13485–compliant site.

Sizes and variants available

  • French sizes: 14, 16, 18, 22.
  • Jejunal lengths (cm): 15, 22, 30, 45.
  • Stoma lengths (cm): approximately 1.0–7.0 (availability depends on diameter).

Measurement note

Jejunal length is measured from the distal aspect of the retention balloon to the catheter tip.

Validated variant specifications (non‑ENFit)

  • Outer diameter: 16 Fr; stoma length: 2.3 cm; jejunal length: 30 cm.
  • Connector: non‑ENFit catheter‑tip feed‑set connector.
  • Tube tip: tapered distal tip.
  • Radiopaque stripe: yes.
  • Medication port: none.
  • Sterile (gamma sterilized); single unit per case.

Packaging (this variant)

  • Case quantity: 1 unit.
  • Approx. package dimensions: 32.258 × 23.876 × 6.096 cm.
  • Approx. weight: 0.560 kg; volume: 4.695 CDM.

Contraindications and cautions

Contraindicated in patients with ascites, colonic interposition, portal hypertension, peritonitis, or morbid obesity.