Description
The MIC-KEY Low Profile Gastric-Jejunal Tube is an advanced medical device designed to provide effective enteral feeding solutions for patients requiring simultaneous gastric decompression and jejunal feeding. Its low-profile design ensures comfort and discretion, making it suitable for both pediatric and adult patients.
Key Features
-
Dual Access Ports: The tube features a jejunal port for direct feeding into the small intestine and a gastric port for stomach decompression, drainage, or venting. These ports can also be used for medication administration if advised by a healthcare provider.
-
Retention Mechanism: An internal silicone balloon secures the tube in place, inflated with sterile or distilled water.
-
Extension Set System: Detachable extension sets connect to the ports with a SECUR-LOK mechanism, providing secure and versatile feeding and medication administration options.
-
Anti-Reflux Valve System: Each port is equipped with one-way anti-reflux valves to enhance safety and functionality.
Design and Material
-
Radiopaque Features: The tube includes a radiopaque stripe and tungsten weighting for easy visualization under imaging, ensuring proper positioning.
-
Medical-Grade Silicone: Constructed from high-quality silicone, the tube is designed for durability and patient comfort.
-
Tapered Distal Tip: This feature aids in non-traumatic insertion and reduces the risk of clogging.
Specifications
-
Available Sizes: French sizes range from 14 Fr to 22 Fr, with stoma lengths from 2.0 cm to 7.0 cm.
-
Jejunal Lengths: Typically 45 cm for adults, with shorter lengths available for pediatric use.
-
Balloon Fill Volume: Varies by model, generally between 3–5 mL.
-
Connector Type: Available in both non-ENFit and ENFit versions.
Kit Contents
Each kit may include:
- MIC-KEY GJ Feeding Tube
- Introducer Cannula
- Continuous and Bolus Feed Extension Sets
- Syringes for balloon management and flushing
- Gauze Pads
- Patient Use and Care Guide
Maintenance and Care
The tube is intended for placement through a gastric stoma, typically via an endoscopic or surgical procedure. Regular maintenance includes cleaning extension sets, flushing the tube, and monitoring the balloon water volume. It is recommended for use under the supervision of a healthcare professional.
Safety Considerations
Designed to minimize the risk of accidental dislodgement, the MIC-KEY Low Profile Gastric-Jejunal Tube requires careful management and consultation with medical professionals for any replacement needs or if discomfort arises. It is a prescription-only device, emphasizing the importance of professional oversight in its use.