Description
The MIC-KEY Low Profile Balloon Gastrostomy Feeding Tube by Avanos Medical is designed for patients requiring long-term enteral feeding, medication delivery, and gastric decompression. Its discreet, low-profile design sits flush against the skin, providing comfort and reducing the risk of accidental dislodgement.
Key Features
-
Balloon Retention Mechanism: The internal silicone balloon secures the tube in place, minimizing trauma during placement and removal. Made from high-clarity, medical-grade silicone, the tube is latex-free and biocompatible.
-
Multiple Ports: Separate ports for feeding, medication, and balloon inflation. The feeding port includes an anti-reflux valve to prevent leakage.
-
Extension Set Compatibility: Works with MIC-KEY extension sets for continuous and bolus feeding, which lock securely and can be disconnected between feeds.
-
Radiopaque Stripe: Allows visualization under imaging for accurate placement.
Size and Sterilization Options
Available in various French sizes and stoma lengths, with balloon fill volumes tailored to each size. The device is sterile and ethylene oxide sterilized, suitable for use in hospitals, homes, and community health settings.
Intended Use
Suitable for neonates, pediatric, and adult patients. Placement can be achieved through various methods, including fluoroscopic, endoscopic, or laparoscopic guidance.
Kit Contents
Contents may vary but typically include:
- Gastrostomy feeding tube
- Continuous and bolus feed extension sets
- Syringes for balloon management and feeding
- Gauze pad
- Patient use and care guide
Care Instructions
- Daily Cleaning: Clean the tube and stoma site with mild soap and water. Rotate the tube as directed.
- Flushing: Use water to flush the tube after feeds and between medications to prevent blockages.
- Balloon Maintenance: Regularly check and maintain the balloon's integrity.
Indications and Contraindications
Indicated for patients unable to tolerate oral intake. Contraindications include conditions like ascites, colonic interposition, and peritonitis.
Potential Complications
Possible issues include tube blockage, balloon deflation, stoma site infection, and accidental displacement. Proper maintenance and monitoring are essential to mitigate these risks.
Troubleshooting
Ensure proper balloon inflation, regular flushing, and timely tube replacement if dislodged. Monitor for infection signs and use only compatible accessories.
Additional Notes
Tube replacement and stoma assessment should be conducted by a healthcare professional. Only use MIC-KEY compatible extension sets to ensure safety and functionality.