MIC-KEY Low Profile Balloon Gastrostomy Feeding Tube - Fr Size: 12Fr Length: 2.7cm
Product information
- Quantity Unit Single
- Product Code 3374239
Sorry. This item is out of stock
Description
The MIC-KEY Low Profile Balloon Gastrostomy Feeding Tube is an essential medical device for patients requiring long-term enteral feeding. Its design is particularly beneficial for those who cannot tolerate oral feeding, are at low risk for aspiration, or need gastric decompression and direct medication delivery into the stomach.
Key Features
-
Discreet Design: The low-profile, skin-level design ensures comfort and discretion, sitting flush against the abdomen. This makes it especially suitable for pediatric and active patients, reducing the risk of accidental dislodgement.
-
Secure Retention: Held in place by an internal inflatable silicone balloon, providing a reliable retention mechanism. The external base sits slightly above the skin to secure the tube while allowing air circulation.
-
Versatile Ports: Equipped with separate ports for enteral feeding and balloon inflation, with some models offering a dedicated medication port. Available with ENFit or Catheter Tip connectors, using the SECUR-LOK connector system for secure attachment of extension sets.
-
Radiopaque Stripe: Includes a radiopaque stripe for radiographic confirmation of placement, and a recessed distal tip to minimize mucosal irritation.
-
Biocompatible Material: Constructed from latex-free silicone, making it suitable for long-term use. Available in various sizes and configurations to meet diverse patient needs.
Placement and Use
The tube can be placed percutaneously under fluoroscopic, laparoscopic, or endoscopic guidance, or as a replacement using an established stoma tract. It serves multiple purposes:
- Long-term enteral feeding
- Gastric decompression
- Direct medication administration
Suitable for neonates, pediatric, and adult patients, it offers a comprehensive solution for diverse patient populations.
Maintenance and Care
-
Daily Care: Involves cleaning the stoma and tube site with warm water and mild soap, rotating the tube daily, and keeping the skin dry.
-
Flushing: Regular flushing of the feeding port with water is essential, before and after feeds and medications.
-
Balloon Maintenance: Weekly checks and refills of the balloon with sterile or distilled water are recommended.
-
Extension Sets: Use only MIC-KEY compatible extension sets, replacing them weekly or as needed.
Safety and Troubleshooting
-
Position Verification: Confirm placement by checking gastric contents' pH. Be aware of common complications such as accidental dislodgement, balloon rupture, and tube blockage.
-
Contraindications: Includes conditions like ascites and portal hypertension. The device is MR Conditional, safe for MRI under specified conditions.
Accessories
Kit configurations may include extension sets, syringes, gauze pads, lubricant, and a patient care guide. These accessories support comprehensive use and care, ensuring the device meets the specific needs of each patient effectively.