Description
The MIC-KEY Low Profile Balloon Gastrostomy Feeding Tube is an innovative medical device crafted by Avanos Medical. It is specifically designed for patients who require long-term enteral feeding, offering a discreet and comfortable solution for both children and adults. This low-profile "button" tube sits flush against the skin, providing ease and subtlety in everyday use.
Key Features
- Comfortable Design: The skin-level design ensures minimal visibility and maximum comfort, making it suitable for active lifestyles.
- Secure Placement: An internal retention balloon, inflatable with sterile or distilled water, secures the tube in place. The balloon fill volumes vary, with recommendations of 3 ml for 12 Fr and 5 ml for 14–24 Fr sizes.
- Durable Construction: Made from soft, biocompatible medical-grade silicone, the tube includes an external retention ring or disc to hold it securely above the skin.
- Enhanced Safety: Features such as a tapered, recessed distal tip reduce insertion trauma, while an anti-reflux valve in the feeding port prevents leakage.
Additional Specifications
- Visibility: Some models include a radiopaque stripe for easy visualization on imaging.
- Hygiene: The device is sterile, latex-free, and intended for prescription use only.
- Connector Options: Available with Catheter Tip or ENFit connectors, and includes extension sets for various feeding needs.
Available Configurations
- Tube Diameters: Ranges from 12 to 24 French.
- Stoma Lengths: Varies from 0.8 cm to 5.0 cm.
- Extension Sets: Includes 12-inch continuous and bolus feed extension sets, along with syringes for maintenance.
Intended Use
The tube facilitates direct delivery of food, liquids, and medications into the stomach, supporting bolus, intermittent, or continuous feeding. It also allows for gastric decompression and venting, catering to both pediatric and adult patients.
Maintenance Guidelines
- Daily Cleaning: The tube and stoma site should be cleaned with mild soap and water.
- Regular Checks: Balloon volume should be monitored weekly, and the tube should be flushed with water to prevent clogging.
- Extension Set Replacement: Recommended every few weeks to ensure optimal functionality.
Contraindications
The device is not suitable for patients with conditions such as ascites, colonic interposition, portal hypertension, peritonitis, or morbid obesity.
Accessories
The kit may include various accessories such as insertion stylets, syringes, and a patient use and care guide, enhancing the overall user experience. Designed for easy replacement by a clinician or trained caregiver, the MIC-KEY feeding tube is compatible with feeding pumps, gravity feeding sets, and syringes, ensuring comprehensive support for those in need.