Description
The Avanos MIC-KEY Low-Profile Balloon Gastrostomy Button is a skin-level, balloon-retained G-tube designed to provide long-term gastric access for enteral nutrition, medication delivery, and gastric decompression in pediatric and adult patients. Prescription use only.
Key features (button)
- Low-profile external base with a covered extension-set port to reduce profile at the skin.
- Internal inflatable retention balloon for secure placement.
- Feeding port includes an anti-reflux valve that remains closed when no extension set is attached.
- High-clarity, medical‑grade silicone construction for visibility and flexibility.
- Sterile; ethylene oxide (EtO) sterilized.
- Not made with natural rubber latex; DEHP-free.
- MR Conditional.
Connectors and compatibility
- Accepts MIC-KEY extension sets via the MIC-KEY SECUR-LOK right‑angle patient-end connector.
- Included extension sets provide ENFit connections (ISO 80369-3) on the feeding side for enteral-only use.
- Use only MIC-KEY extension sets with the MIC-KEY button; other brands’ extension sets are not interchangeable.
- Enteral-only connections; do not connect to breathing systems or driving gases.
Included extension sets (typical kit)
- Two ENFit extension sets with SECUR-LOK right‑angle patient-end connectors:
- 12-inch (≈30 cm) Continuous Feed extension set with Y-connector and medication port; integrated tubing clamp.
- 12-inch (≈30 cm) Bolus Feed extension set (ENFit).
- Extension sets are non-sterile; reusable for single‑patient use; not made with natural rubber latex; DEHP-free.
Sizes and fit
- French sizes: 12, 14, 16, 18, 20, 24 Fr.
- Stoma (shaft) lengths (cm): 0.8, 1.0, 1.2, 1.5, 1.7, 2.0, 2.3, 2.5, 2.7, 3.0, 3.5, 4.0, 4.5, 5.0.
- Example validated variant: 16 Fr, 2.0 cm stoma length.
Balloon inflation guidance
- Inflate the retention balloon with sterile or distilled water only.
- 12 Fr: recommended 3 mL; maximum 5 mL.
- 14–24 Fr: recommended 5 mL; maximum 10 mL.
Placement
- May be placed percutaneously under fluoroscopic, laparoscopic, or endoscopic guidance.
- Suitable as a replacement device via an established stoma tract.
Safety and handling
- Single-patient device; do not resterilize; do not use if packaging is compromised.
- Verify French size and stoma length selection before placement and feeding.
- Confirm secure SECUR-LOK engagement and valve patency prior to use.
- This listing is for the gastrostomy (G) button configuration only; gastro‑jejunal device features do not apply.