/

MIC ENFit Gastrojejunal Feeding Tube (22Fr · Tube Only · 45cm)

Product information

  • Quantity Unit Carton
  • Contains 1 Singles
  • Product Code 846509160

$764.40 incl GST

Description

The Avanos MIC ENFit Gastrojejunal (GJ) Feeding Tube is a balloon‑retained, standard‑length, transgastric‑jejunal device with double lumens designed to support simultaneous jejunal feeding and gastric decompression/drainage in pediatric and adult patients who cannot adequately absorb via the stomach (e.g., intestinal dysmotility, gastric outlet obstruction, severe reflux/aspiration risk, post‑esophagectomy/gastrectomy). The jejunal port may also be used for medication delivery when clinically appropriate.

Key Features and Design

  • Double‑lumen configuration with separate channels for gastric drainage and jejunal feeding
  • Male ENFit connectors on both gastric and jejunal ports; clearly labeled; no separate medication port
  • Internal silicone retention balloon; typical fill volume 7–10 mL (size‑dependent)
  • SECUR‑LOK external retention ring for secure external fixation and stoma length adjustment
  • Tapered distal tip with multiple jejunal exit ports to support distal delivery
  • Radiopaque construction for imaging: tungsten‑weighted jejunal segment and barium‑sulfate radiopaque stripe on gastric segment
  • Soft, medical‑grade silicone composition; not made with natural rubber latex, DEHP, DBP, or BBP
  • Sterile, single‑use device; do not re‑use, re‑process, or re‑sterilize

Placement and Measurement

  • Suitable for initial endoscopic or fluoroscopic placement and for replacement in an established stoma tract
  • Jejunal length is measured from the distal aspect of the retention balloon to the catheter tip
  • Radiopaque features assist with visualization during placement and verification

Sizes and Options (ENFit)

  • 16 Fr outer diameter: jejunal lengths 15 cm, 22 cm, 30 cm, 45 cm
  • 18 Fr outer diameter: jejunal lengths 22 cm, 30 cm, 45 cm
  • 22 Fr outer diameter: jejunal length 45 cm

Included Components (typical kit)

  • GJ tube with ENFit connectors
  • Placement guidewire
  • 35 mL catheter‑tip syringe
  • 6 mL luer‑slip syringe
  • SECUR‑LOK external retention ring
  • Directions for use and patient care guidelines

Contraindications

  • Ascites
  • Colonic interposition
  • Portal hypertension
  • Peritonitis
  • Morbid obesity

Notes

  • Specification pertains to the standard MIC ENFit GJ tube (standard length). A separate low‑profile MIC‑KEY GJ “button” variant exists and differs in form factor and accessories.

GoSupply

Unit 9/15-17 Gartmore Ave Bankstown NSW 2200

info@gosupply.com.au

1800 299 962

Mon-Fri 9am - 5pm AEDT

GoSupply PTY LTD, ABN: 51 660 241 903

Solutions

© 2026 GoSupply. All rights reserved.