Flocare Nasogastric Feeding Tube 110 cm (CH8)

Product information

  • Quantity Unit Carton
  • Contains 10 Singles
  • Product Code 445262246

$466.50 incl GST

Description

The Nutricia Flocare PUR ENFit Nasogastric Feeding Tube (CH12, 110 cm) is a medical‑grade polyurethane tube designed for short‑term gastric feeding in adults and children. Its transparent PUR construction is latex‑free and DEHP‑free, supporting patient safety and comfort during use. The tube incorporates features that assist accurate placement verification, safe insertion, and reliable enteral connection via an ENFit patient‑end interface.

Key features

  • Open, rounded tip with distal and lateral outlets to support flow and facilitate insertion
  • Siliconised guidewire with a welded ball tip; guidewire terminates before the first lateral hole to help protect mucosa during placement
  • Three white radiopaque lines for visibility under imaging
  • 1 cm graduation markings to assist depth and position checks
  • Colour‑coded size identification for quick recognition on the ward
  • Transparent tubing to aid visual inspection

Specifications

  • Size/length: CH12; 110 cm
  • Material: Medical‑grade polyurethane (PUR); latex‑free and DEHP‑free
  • Connector: ENFit patient‑end connection (ENFit‑compatible)
  • Maximum indwelling time: 6–8 weeks (short‑term use)

Indications and suitability

  • Intended for short‑term gastric feeding only
  • Suitable for adults and children; select tube size according to clinical judgement

Important precautions and use guidance

  • Do not use in patients with delayed gastric emptying or those at risk of aspiration
  • Begin feeding only after confirming correct placement per local guidelines (e.g., X‑ray or gastric pH); do not use if position is uncertain
  • If respiratory distress occurs at any time, stop feeding and seek urgent medical advice
  • Maintain hygiene and aseptic handling during insertion and use
  • Flush the tube before and after feeds and medications, and at least three times daily, to help maintain patency
  • Replace the tube every 6–8 weeks or sooner if clinically indicated

This tube is intended for gastric delivery of nutrition, fluids, and medications under professional supervision. Follow institutional protocols for insertion, verification, use, and removal.