Description
The ENFit MIC Balloon Gastrostomy Tube by Avanos is a specialized medical device designed to facilitate enteral nutrition and medication delivery for patients unable to tolerate oral feeding. Suitable for both pediatric and adult patients, this gastrostomy tube serves those requiring long-term or short-term enteral feeding, gastric decompression, or direct medication delivery into the stomach.
Key Features
- Material: Crafted from medical-grade silicone, the tube offers flexibility, softness, and biocompatibility, ensuring patient comfort and safety.
- Retention Mechanism: Equipped with an inflatable silicone balloon for secure internal retention and a SECUR-LOK external retention ring for stability and a snug fit.
- Connector System: Utilizes ENFit connectors adhering to ISO 80369-3 standards, minimizing misconnection risks and providing a secure, leak-resistant connection.
- Port Design: Features dedicated gastric ports for feeds, medications, and water flushes, along with a balloon port for inflation.
- Tip Design: Includes a tapered or recessed distal tip to enhance placement ease and patient comfort.
- Radiopaque Stripe: Integrated for visibility under X-ray or imaging.
Sterility and Configuration
- Sterilization: The tube is gamma sterilized, ensuring a high level of hygiene.
- Size Variations: Available in various French sizes ranging from 12Fr to 30Fr, with corresponding balloon volumes tailored to each size.
Intended Use and Placement
The device is intended solely for gastric use, with no jejunal port, and can be placed surgically or percutaneously under fluoroscopic or endoscopic guidance. It is also suitable for replacement via an established stoma tract.
Maintenance and Care
- Balloon Maintenance: Balloon volume should be checked weekly and refilled with sterile or distilled water.
- Cleaning: Daily cleaning is recommended, with rotation after initial healing to prevent skin adherence.
- Flushing: The tube should be flushed with warm water to prevent blockages, using the correct extension tubes specific to the brand.
Troubleshooting and Safety
Common issues such as leakage, blockage, or skin irritation may require troubleshooting. Proper use of ENFit connectors is advised to avoid breakage, and feeding or medication should only be administered via the designated ENFit feeding port. The device is intended for prescription use only, emphasizing the importance of professional oversight.
Additional Information
The ENFit MIC Balloon Gastrostomy Tube is tailored to individual patient needs, with specific tube sizes and balloon volumes. It is crucial to note that extension tubes from other brands are not interchangeable, ensuring compatibility and safety in use.